NAME d2scan - two-motor scan relative
to the starting positions
SYNOPSIS d2scan motor1
start1 end1 motor2 start2 end2
intervals time
DESCRIPTION d2scan scans two motors,
as specified by motor1 and
motor2. Each motor moves the same number of
intervals. If each motor is at a position X
before the scan begins, it will be scanned from
X+start to
X+end. The step size for
each motor is
(start-end)/intervals.
The number of data points collected will be
intervals+1. Count time is given by
time, which if positive, specifies seconds
and if negative, specifies monitor counts.
Upon termination, the motors are returned to their starting
positions.
EXAMPLE d2scan th -1 1 phi -2 2 20 10
SEE ALSO
motors
ascan
a2scan
a3scan
dscan
d3scan
mesh
... Meeting the software needs of scientists since 1985 ...